There is no single answer. Required depth depends on the kind of line, the material it is in, the voltage, and what sits above it, and the local code and the utility have the final say. Your electrician, plumber or gas company sets the depth, and the excavator digs to it.
Electrical
Underground wiring depth comes from the electrical code your city has adopted, usually based on the National Electrical Code. Common minimums people hear are 24 inches of cover for direct-burial cable, 18 inches for PVC conduit and 6 inches for rigid metal conduit, with different numbers for some residential circuits and for runs under driveways. Your electrician knows which applies to your run and whether the trench will be inspected. See electrical trenching.
Gas
Gas line depth depends on the pipe material, whether it is the utility's service line or a private line after the meter, and local code. Plastic gas lines are laid with a tracer wire so they can be found later. Your plumber or the gas company sets the depth. See gas line trenching.
Water
The main concern for water lines is freezing. They need to sit below the depth where the ground freezes in a hard winter, which your plumber and local code set for your area. Lines to stock tanks and outbuildings need the same protection. See water line excavation.
Sewer
Sewer depth is set by the slope the pipe needs to drain. A lateral usually starts shallow where it leaves the house and gets deeper toward the main. Depth is a result of the slope, not a fixed number.
Sharing a trench
Power and water to the same building can sometimes share a trench if they are separated the right way and code allows it. Gas usually has its own rules. Ask your trades before the trench gets dug, because it changes how wide we dig it.
Backfill matters too
The first few inches around a line should be clean fill with no sharp rock, so the line is not damaged when the trench is packed. Warning tape is often laid above buried lines so the next person who digs finds the tape first.
Common Questions
Who decides how deep the trench is?
The trade setting the line, following the code your city or county has adopted and the utility's rules.
Does the trench get inspected?
Many do, especially electrical and gas. The trench stays open until it passes, then gets backfilled.
Can you dig the trench before the electrician comes?
Yes, if we know the depth and route. Most of the time we coordinate with the trade.
What to Do Next
Need a trench to a shop, a barn, a generator or a new house? Call (918) 320-3439 with the run and the depth your trade needs.